Search
Close this search box.

Motorizations for sectional doors

400 V, 50 – 60 Hz three-phase gearmotor applied to the shaft of the balancing springs.

The gearmotor has different dimensions and performances related to the dimension of the sectional door.

OPERATION

Doors larger than 3 x 3 meters, require a gearmotor fitted to the shaft of the balancing springs.

Cables derailing and breaking is one ne of the most frequent problems with a gearmotor rising and lowering the door.  When the door accidentally hits the loading ramp connected to the vehicle floor and the lower limit switch of the gearmotor is set to stop the door at floor level, the motor continues to run, releases the cables down to floor level and generates cables’ derailing and overlapping which breaks the cables at the next ascent.

GEARMOTOR 1

Direct drive gearmotor 230V 0.37 kW 50Hz Single-phase – 70 Nm, 19 Rpm, Control protection class IP65 (motor IP54), Class ds S3 25%, Insulation class. 1, Operating temperature -10 ° C + 55 ° C, 8m of chain for manual release, including control panel with push-button for Man-Present operation.

Max door weight 400 kg

Max door size 1,8 m² , 5 m  cable for the control button, logic board in the gearmotor protection casing

GEARMOTOR 2

Direct drive gearmotor 230V 0.37 kW 50Hz Single-phase – 70 Nm, 19 Rpm, Control protection class IP65 (motor IP54), Class ds S3 25%, Insulation class. 1, Operating temperature -10 ° C + 55 ° C, 8m of chain for manual operation, including control keypad for automatic operation, Man Present Pulse Ascent Descent.

Max door weight 400 kg

Max door size 18 m², 5 m cable for the control button, logic board in the gearmotor protection casing

GEARMOTOR 3

Direct drive gearmotor 400V 0.55 kW 50 Hz Three-phase – 100 Nm, 24 rpm, Panel protection class IP65 (motor IP54), Class ds S3 60%, Insulation class. 1, Operating temperature -10 ° C + 45 ° C, 10m of chain for manual operation, 7m of cable between control panel and gearmotor, control panel for automatic operation, Man Present, Man Present impulse ascent, descent.

Max door weight 500 Kg

Max door area 35 m² ^ 2

GEARMOTOR 4

Direct drive gearmotor 400V 0.55 kW 50 Hz Three-phase – 120 Nxm, 19 rpm, Panel protection class IP65 (motor IP54), Class ds S3 60%, Insulation class. 1, Operating temperature -10 ° C + 45 ° C, 10m of chain for manual operation, 7m of cable between control panel and gearmotor, control panel for automatic operation, Man Present, Man Present impulse ascent, descent.

Max door weight 600 Kg

Max door area 45 m²

The control system of the gearmotor can be integrated with additional options on request.

Lifting system built in compliance with the EN 13241 Product Standards and the Machinery Directive.

CE marking.

Three-phase power supply 230-400V, 50/60 Hz, from 0.75 kW upwards, according to the size of the door.

Request a free quote

Request a free quote

Get your free consultation to find out together with our technical specialists what are the best logistics solutions for your industry.


Looking for other solutions?